EDS-405AϵÁÐ

5¿ÚÈëÃż¶Íø¹ÜÐÍÒÔÌ«Íø½»Á÷»ú

  • Ö§³ÖTurbo Ring  £¬ Turbo Chain(×ÔÓúʱ¼ä< 20ºÁÃë @ 250½»Á÷»ú)  £¬ RSTP/STPºÍMSTPÓÃÓÚÒÔÌ«ÍøÈßÓà
  • Ö§³ÖIGMP Snooping  £¬ QoS  £¬ IEEE 802.1Q VLANºÍPortbased VLAN
  • ͨ¹ýÍøÒ³ä¯ÀÀÆ÷  £¬ CLI  £¬ Telnet/Serial console  £¬ Windows utilityºÍABC-01ÇáËÉÖÎÀíÍøÂç
  • PROFINET»òEtherNet/IPĬÈÏÆôÓã¨PN»òEIPÐͺţ©
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EDS-405 A ϵÁÐרΪ¹¤ÒµÓ¦ÓöøÉè¼Æ ¡£Õâ¿î½»Á÷»úÅ䱸ÖÖÖÖÊÊÓõÄÖÎÀí¹¦Ð§  £¬ÀýÈ磺Turbo Ring¡¢Turbo Chain¡¢»·ÍøñîºÏ¡¢IGMP Snooping¡¢IEEE 802.1Q VLAN¡¢»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢QoS¡¢RMON¡¢´ø¿íÖÎÀí¡¢¶Ë¿Ú¾µÏñ  £¬ÒÔ¼°Í¨¹ýµç×ÓÓʼþ»ò¼ÌµçÆ÷·¢³öÖÒÑÔ ¡£Ê¹Óà Web ÖÎÀí½çÃæ»ò EDS-405 A ½»Á÷»ú¶¥²¿Ãæ°åÉ쵀 DIP ¿ª¹Ø  £¬¼´¿ÉÇáËÉÉèÖà Turbo Ring ¡£

ÆäËûÌصãºÍÓÅÊÆ
?DHCP Option 82  £¬ÓÃÓÚ²î±ðÕ½ÂÔ·ÖÅÉ IP µØµã
?Ö§³Ö EtherNet/IP¡¢Modbus TCP ºÍ PROFINET  £¨½ö EDS-405 A-PN ϵÁУ©Ð­ÒéµÄ×°±¸ÖÎÀíºÍ¼à¿Ø
?Ö§³Ö EtherNet/IP EDS£¨µç×ÓÊý¾Ý±í£©Îļþ¡¢×Ô½ç˵ AOI£¨¸½¼ÓÖ¸ÁºÍ FactoryTalk? View ¿ÉÊÓ»¯Ãæ°å
?Ìṩ PROFINET GSDML ÎļþºÍ SIMATIC STEP 7 ×°±¸Í¼±ê £¨½ö EDS-405 A-PN ϵÁУ©
?Ö§³Ö¶Ë¿Ú¾µÏñ¹¦Ð§  £¬±ãÓÚÔÚÏßµ÷ÊÔ
?»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢IEEE 802.1Q VLAN ºÍ GVRP  £¬¿É¼ò»¯ÍøÂçÍýÏë
?QoS£¨IEEE 802.1p ºÍ TOS/DiffServ£©Ìá¸ßÁËÍøÂçÎȹÌÐÔ
?RMON Ö§³Ö×Ô¶¯ÍøÂç¼à¿Ø
?SNMPv1/v2c/v3 Ö§³ÖÓÃÓÚ²î±ð¼¶±ðµÄÍøÂçÖÎÀí
?´ø¿íÖÎÀí  £¬¿ÉÔ¤·À·ºÆð²»Îȹ̵ÄÍøÂç״̬

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100BaseT(X) ¶Ë¿Ú£¨RJ45 ÌÖÂÛ£© £º
EDS-405 A  £¬405 A-EIP/PN/PTP ϵÁУº5
EDS-405 A-MM-SC/MM-ST/SS-SC ϵÁУº3

ËùÓÐÐͺžùÖ§³Ö£º
ËÙÂÊ×Ô˳Ӧ
È«/°ëË«¹¤Ä£Ê½
×Ô¶¯ MDI/MDI-X ÅþÁ¬
100BaseFX ¶Ë¿Ú£¨¶àÄ£ SC ÌÖÂÛ£© £ºEDS-405 A-MM-SC ϵÁУº2
100BaseFX ¶Ë¿Ú£¨¶àÄ£ ST ÌÖÂÛ£© £ºEDS-405 A-MM-ST ϵÁУº2
100BaseFX ¶Ë¿Ú£¨µ¥Ä£ SC ÌÖÂÛ£© £ºEDS-405 A-SS-SC ϵÁУº2
¹âÏË£º
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±ê×¼ £º
IEEE 802.3  £¬ÓÃÓÚ 10BaseT
IEEE 802.3u  £¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.3x  £¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.1D-2004  £¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1p  £¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.1Q  £¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1w  £¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ýÂË £º802.1Q VLAN¡¢GMRP¡¢GVRP¡¢IGMP v1/v2¡¢»ùÓÚ¶Ë¿ÚµÄ VLAN
¹¤ÒµÐ­Òé £º
EtherNet/IP  EDS-405 A-EIP ϵÁУºÄ¬ÈÏÇéÐÎÏÂÆôÓà EtherNet/IP ЭÒé ¡£ Modbus TCP
EDS-405 A-PN ϵÁУºPROFINET IO Device (Slave)
ÖÎÀí £º
Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢BOOTP¡¢DHCP Option 66/67/82¡¢DHCP Server/Client¡¢Flow control£¨Á÷Á¿¿ØÖÆ£©¡¢IPv4/IPv6¡¢LLDP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢RARP¡¢RMON¡¢SMTP¡¢SNMP Inform¡¢SNMPv1/v2c/v3¡¢Syslog¡¢Telnet¡¢TFTP 
MIB £º Bridge MIB¡¢Ethernet-like MIB¡¢MIB-II¡¢P-BRIDGE MIB¡¢RMON MIB Groups 1¡¢2¡¢3¡¢9¡¢RSTP MIB
ÈßÓàЭÒé £ºRSTP¡¢STP¡¢Turbo Chain¡¢Turbo Ring v1/v2
¶ÔʱЧÀÍ £º
ËùÓÐÐͺţºNTP Server/Client, SNTP
EDS-405 A-PTP ϵÁУº»ùÓÚÓ²¼þµÄ IEEE 1588v2 PTP

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×é £º256
MAC µØµã±í¾Þϸ £º
EDS-405 A ϵÁС¢EDS-405 A-EIP/MM-SC/MM-ST/PN/SS-SC ϵÁУº2 K
EDS-405 A-PTP ϵÁУº8 K
VLAN ÊýÄ¿£¨max£© £º64
Êý¾Ý°ü»º³åÇø¾Þϸ £º1 Mb
ÓÅÏȼ¶ÐÐÁÐ £º4
VLAN ID ¹æÄ£ £ºVID 1 ÖÁ 4094

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú £ºRS-232£¨TxD¡¢RxD¡¢GND£©  £¬10-pin RJ45£¨19200¡¢n¡¢8¡¢1£©

DIP ¿ª¹ØÉèÖÃ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÒÔÌ«Íø½Ó¿Ú £ºTurbo Ring¡¢Master¡¢ñîºÏÆ÷¡¢Ô¤Áô

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ £º´¿µç×èÐÔ¸ºÔØ£º1 A @ 24 VDC

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊäÈëµçѹ £º12/24/48 VDC  £¬ÈßÓàË«µçÔ´ÊäÈë
ÊÂÇéµçѹ £º9.6 ÖÁ 60 VDC
ÊäÈëµçÁ÷ £º
EDS-405 A/405 A-T  £¬EDS-405 A-EIP/PN ϵÁУº0.21 A @ 24 VDC
¹âÏËÐͺţº0.26 A @ 24 VDC
PTP Ðͺţº0.23 A @ 24 VDC
¹ýÔصçÁ÷±£»¤ £ºÖ§³Ö
·´½Ó±£»¤ £ºÖ§³Ö
ÅþÁ¬ £º1 ¸ö¿É²ðж 6 ´¥µã½ÓÏ߶Ë×Ó

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç £º½ðÊô
IP Æ·¼¶ £ºIP30
³ß´ç £º53.6 x 135 x 105 mm£¨2.11 x 5.31 x 4.13 Ó¢´ç£©
ÖØÁ¿ £º
EDS-405 A-EIP/MM-SC/MM-ST/PN/SS-SC ϵÁУº650 g (1.44 lb)
EDS-405 A-PTP ϵÁУº820 g (1.81 lb)
×°Öà £ºµ¼¹ìʽװÖà  £¬±Ú¹ÒʽװÖ㨴ø¿ÉÑ¡Ì×¼þ£©

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéÎÂ¶È £º
±ê×¼Ðͺţº-10 ÖÁ 60¡ãC£¨14 ÖÁ 140¡ãF£©
¿íÎÂÐͺţº-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£© £º-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È £º5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
SAFETY£º
ËùÓÐÐͺţºUL 508
·Ç PTP ÐͺţºUL 60950-1
EMC £ºEN 55032/24
EMI £ºCISPR 32  £¬FCC Part 15B Class A
EMS £º
·Ç PTP Ðͺţº
IEC 61000-4-2 ESD£º½Ó´¥£º6 kV£»¿ÕÆø£º8 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º20 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º2 kV£»Ðźţº2 kV
IEC 61000-4-5 Surge£ºµçÔ´£º2 kV£»Ðźţº2 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8

PTP Ðͺţº
IEC 61000-4-2 ESD£º½Ó´¥£º4 kV£»¿ÕÆø£º8 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º3 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º0.5 kV£»Ðźţº0.5 kV
IEC 61000-4-5 Surge£ºµçÔ´£º0.5 kV£»Ðźţº1 kV
IEC 61000-4-6 CS£º3 V
IEC 61000-4-8
ΣÏÕÇéÐÎ £º·Ç PTP ÐͺţºATEX  £¬Class I Division 2
º£Ê £º·Ç PTP ÐͺţºDNV-GL
½»Í¨¿ØÖÆ £º·Ç PTP ÐͺţºNEMA TS2
×ÔÓÉÂäÌå £ºIEC 60068-2-31
¹¥»÷ £ºIEC 60068-2-27
Õñ¶¯ £ºIEC 60068-2-6

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä £º
EDS-405 A/405 A-T  £¬EDS-405 A-EIP/PN ϵÁУº1,547,941 Сʱ
EDS-405 A-MM-SC/MM-ST/SS-SC ϵÁУº1,429,327 Сʱ
EDS-405 A-PTP ϵÁУº1,316,464 Сʱ
±ê×¼ £ºTelcordia (Bellcore)  £¬GB

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÏÞÆÚ £º5 Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿