ºèÔ˹ú¼Ê

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

EDR-G903ϵÁÐ

¹¤Òµ¼¶Ç§Õ×·À»ðǽ/NAT/VPN safety·ÓÉÆ÷

  • ÜöÝÍ·À»ðǽ¡¢NAT¡¢VPN¡¢Â·ÓÉÆ÷¹¦Ð§ÓÚÒ»Ìå
  • ʹÓÃVPN±£»¤Ô¶³Ì»á¼ûËíµÀ
  • ¸ßÐÔÄÜǧÕ×RJ45/¹âÏ˸´ºÏ¶Ë¿Ú
  • ÍøÂçµØµãת»»£¨N¶Ô1 £¬1¶Ô1ºÍ¶Ë¿Úת·¢£©
  • ʹÓÃPacketGuardÊÖÒÕ¼ì²é¹¤ÒµÐ­Òé
  • Õë¶Ô¹«ÍøµÄË«WANÈßÓà½Ó¿Ú
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EDR-G903 ÊÇÒ»¿î¸ßÐÔÄܹ¤Òµ¼¶ VPN safety·ÓÉÆ÷ £¬¼¯·À»ðǽ/NAT ÓÚÒ»Ìå ¡£ÕâÊÇÒ»¿îרΪҪº¦Ô¶³Ì¿ØÖÆ»òÔ¶³Ì¼à¿ØÍøÂçµÄÒÔÌ«ÍøsafetyÓ¦ÓöøÉè¼ÆµÄ²úÆ· £¬Ìṩµç×Ósafety½çÏß (ESP) À´±£»¤Òªº¦ÍøÂç×ʲú £¬ÀýÈ磺±ÃÕ¾ÖеÄË®´¦Öóͷ£ÏµÍ³¡¢ÓÍÆøÓ¦ÓÃÖÐµÄ DCS ϵͳ £¬ÒÔ¼°¹¤³§×Ô¶¯»¯ÖÐµÄ PLC/SCADA ϵͳ ¡£EDR-G903 ϵÁаüÀ¨ÒÔÏÂÍøÂçsafetyÌØÕ÷£º

? VPN£ºÐéÄâרÓÃÍøÂç (VPN) ΪÓû§Í¨¹ý¹«¹²»¥ÁªÍø»á¼ûרÓÃÍøÂçʱ £¬ÌṩsafetyͨѶËíµÀ ¡£VPN ʹÓà IPsec£¨IP safety£©server »ò client ģʽ¼ÓÃܺÍÈÏÖ¤ÍøÂç²ãµÄ IP Êý¾Ý°ü £¬ÒÔÈ·±£ÉñÃØÐԺͷ¢ËÍ·½Éí·ÝÈÏÖ¤ ¡£

? ·À»ðǽ£º·À»ðǽսÂÔ¿ØÖƲî±ðÐÅÍÐÇøÖ®¼äµÄÍøÂçÁ÷Á¿ £¬¶øÍøÂçµØµãת»» (NAT) ÔòÊDZ£»¤ÄÚ²¿¾ÖÓòÍø £¬ÃâÊÜÀ´×ÔÍⲿÖ÷»úµÄδÊÚȨÔ˶¯ ¡£

EDR-G903 µÄ¿ìËÙ×Ô¶¯»¯ÉèÖÃÎļþ¹¦Ð§Ö§³Ö³£¼ûµÄÏÖ³¡×ÜÏßЭÒé £¬°üÀ¨ EtherCAT¡¢EtherNet/IP¡¢FOUNDATION Fieldbus¡¢Modbus TCP ºÍ PROFINET ¡£Óû§Ö»Ðè¼òÆÓµã»÷Óû§ÓѺÃÉè¼ÆµÄ Web UI £¬¼´¿ÉÇáËɽ¨ÉèÒ»¸ösafetyµÄÒÔÌ«ÍøÏÖ³¡×ÜÏßÍøÂç ¡£±ðµÄ £¬Moxa PacketGuard ÊÖÒÕ£¨Éî²ãÊý¾Ý°ü¼ì²â£©¿ÉÔÚ OSI µÚÆß²ã¹ýÂË Modbus TCP ÏÂÁî ¡£Õâ¿î²úÆ·Ìṩ¿íÎÂÐͺÅ £¬¿ÉÔÚ -40 ÖÁ 75¡ãC ζȵÄΣÏÕÇéÐÎÏ¿ɿ¿ÔËÐÐ ¡£



ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ :´¿µç×èÐÔ¸ºÔØ£º1 A @ 24 VDC
°´Å¥ :¸´Î»°´Å¥
Êý×ÖÊäÈëͨµÀ :
+13 ÖÁ +30 V ÌåÏÖ״̬ 1
-30 ÖÁ +3 V ÌåÏÖ״̬ 0
¼«ÏÞÊäÈëµçÁ÷£º8 mA
¼ÌµçÆ÷ͨµÀ :1

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Combo ¶Ë¿Ú£¨10/100/1000BaseT(X) »ò 100/1000BaseSFP+£© :3
±ê×¼ :
IEEE 802.1Q £¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.3 £¬ÓÃÓÚ 10BaseT
IEEE 802.3ab £¬ÓÃÓÚ 1000BaseT(X)
IEEE 802.3u £¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.3x £¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.3z £¬ÓÃÓÚ 1000BaseSX/LX/LHX/ZX
WAN ¶Ë¿Ú £¬RJ45/¹âÏË Combo ¶Ë¿Ú :1
DMZ ¶Ë¿Ú £¬RJ45/¹âÏË Combo ¶Ë¿Ú :1
LAN ¶Ë¿Ú £¬RJ45/¹âÏË Combo ¶Ë¿Ú :1

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÖÎÀí :Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢DDNS¡¢DHCP Server/Client¡¢HTTP¡¢LLDP¡¢QoS/CoS/ToS¡¢SMTP¡¢SNMPv1/v2c/v3¡¢Telnet¡¢TFTP
·ÓÉ :ÍÌÍÂÁ¿£ºÃ¿Ãë 40,000 ¸öÊý¾Ý°ü£¨¿É´ï 500 Mbps£©
·ÓÉÈßÓà :VRRP
Safe :HTTPS/SSL¡¢SSH¡¢IPsec¡¢OpenVPN£¨client ºÍ server£©¡¢UDP ºÍ TCP ËíµÀģʽ£¨Â·ÓÉ£©¼° TAP ģʽ (bridge)¡¢L2TP (server)¡¢RADIUS
¶ÔʱЧÀÍ :NTP Server/Client¡¢SNTP
µ¥²¥Â·ÓÉ :OSPF £¬RIPV1/V2 £¬¾²Ì¬Â·ÓÉ

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¼«ÏÞ VLAN ÊýÄ¿ :15

DoS ºÍ DDoS ±£»¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÖÒÕ :ARP-Flood, FIN Scan, ICMP-Death, NEWWithout-SYN Scan, NMAP-ID Scan, NMAP-Xmas Scan, Null Scan, SYN/FIN Scan, SYN/RST Scan, SYN-Flood, Xmas Scan

ÍøÂçЭÒé·À»¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Éî²ãÊý¾Ý°ü¼ì²â :
Modbus TCP
Modbus UDP
¹ýÂË :DDoS¡¢ÒÔÌ«ÍøЭÒé¡¢ICMP¡¢IP µØµã¡¢MAC µØµã¡¢¶Ë¿Ú
¿ìËÙ×Ô¶¯»¯ÉèÖÃÎļþ :DNP¡¢EtherCAT¡¢EtherNet/IP¡¢FOUNDATION Fieldbus¡¢FTP¡¢HTTP¡¢IEC 60870-104¡¢IPsec¡¢L2TP¡¢LonWorks¡¢Modbus TCP¡¢PPTP¡¢PROFINET¡¢RADIUS¡¢SSH¡¢Telnet
״̬¼ì²â :
·ÓÉÆ÷·À»ðǽ
͸Ã÷ (bridge) ·À»ðǽ
ÍÌÍÂÁ¿ :ÿÃëÖÁ¶à 40000 ¸öÊý¾Ý°ü£¨¿É´ï 500 Mbps£©

IPsec VPN

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÈÏÖ¤ :
MD5 ºÍ SHA (SHA-256)
RSA£¨ÃÜÔ¿´óÐ ¡£º1024 λ £¬2048 룩
X.509 v3 Ö¤Êé
VPN ²¢·¢ËíµÀ :ÖÁ¶à 100 ¸ö IPsec VPN ËíµÀ
¼ÓÃÜ :3DES, AES-128, AES-192, AES-256, DES
ЭÒé :IPsec¡¢L2TP (server)¡¢PPTP (client)
ÍÌÍÂÁ¿ :¿É´ï 150 Mbps£¨Ìõ¼þ£ºAES-256¡¢SHA-256£©

NAT

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÌØÕ÷ :1 ת 1 £¬N ת 1 £¬¶Ë¿Úת·¢

OpenVPN

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÈÏÖ¤ :Óû§ÃÜÂë £¬½ÓÄÉ MD5 ºÍ SHA1 Ëã·¨
VPN ²¢·¢ËíµÀ :
Client ģʽ£ºÖÁ¶à 2 ¸öÍⲿ server
Server ģʽ£ºÖÁ¶à 5 ¸öÍⲿ client
¼ÓÃÜ :AES-128/192/256 CBC, Blowfish CBC, DES CBC, DES-EDE3 CBC
ЭÒé :OpenVPN£¨client ºÍ server£©¡¢UDP ºÍ TCP ËíµÀģʽ£¨Â·ÓÉ£©¼° TAP ģʽ (bridge)¡¢ËíµÀģʽ£¨Â·ÓÉ£©

ʵʱ·À»ðǽ/VPN ÊÂÎñÈÕÖ¾

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÎñÀàÐÍ :·À»ðǽÊÂÎñ¡¢ÏµÍ³ÊÂÎñ¡¢VPN ÊÂÎñ
½Ó¿Ú :ÍâµØ´æ´¢¡¢SNMP Trap¡¢Syslog server

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú :Web/Telnet/SSH/CLI ºÍ RS-232 ´®¿Ú console

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéÎÂ¶È :
EDR-G903£º0 ÖÁ 60¡ãC£¨32 ÖÁ 140¡ãF£©
EDR-G903-T£º-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£© :-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È :5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
×ÔÓÉÂäÌå :IEC 60068-2-32
EMC :EN 55032/24
EMI :CISPR 32 £¬FCC Part 15B Class A
EMS :
IEC 61000-4-2 ESD£º½Ó´¥£º6 kV£»¿ÕÆø£º8 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º10 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º4 kV£»Ðźţº4 kV
IEC 61000-4-5 Surge£ºµçÔ´£º2 kV£»Ðźţº1 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
Safe :UL 508
¹¥»÷ :IEC 60068-2-27
Õñ¶¯ :IEC 60068-2-6
±äµçÕ¾ :IEC 61850-3

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä :903,311 Сʱ
±ê×¼ :Telcordia (Bellcore) £¬GB

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÏÞÆÚ £º5 Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿