TN-4500AϵÁÐ

EN 50155 12+4G/24+4G ¿ÚǧÕ×ÒÔÌ«Íø½»Á÷»ú

  • ¶à´ï 4 ¸öǧÕ׶˿Ú£¬Ö§³Ö PoE ¹¦Ð§
  • 24 ÖÁ 110 VDC ¸ôÀëµçÔ´ÊäÈë
  • ¹âÏËÐͺÅÅäÓÐ 2 ¸öǧÕ×¹âÏ˶˿Ú£¬ÄÚǶ¶àÄ£ Q-ODC® ½Ó¿Ú
  • ÅÔ·ÐͺÅÅäÓÐ 2 ¸öǧÕ׶˿Ú£¬¾ß±¸ÅÔ·Öм̹¦Ð§
  • ÇкÏËùÓÐ EN 50155 Ç¿ÖÆÐÔ²âÊÔÏîÄ¿ ±¾²úÆ·ÊÊÓÃÓÚ EN 50155 ±ê×¼½ç˵µÄ¹ìµÀ³µÁ¾¹ì½»Ó¦Óá£ÓйØÏêϸ˵Ã÷£¬Çë²ÎÔÄ£ºwww.moxa.com/doc/specs/EN_50155_Compliance.pdf
  • Ö§³Ö -40 ÖÁ 75¡ãC ÊÂÇéζÈ
  • Ö§³Ö Turbo Ring ºÍ Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms @ 250 ̨½»Á÷»ú£©£¬ÒÔ¼° RSTP/STP/MSTP ÍøÂçÈßÓà
  • ¶à´ï 20 ¸öÇÐºÏ IEEE 802.3at/af ±ê×¼µÄ PoE ¶Ë¿Ú
  • ÿ¸ö PoE ¶Ë¿Ú¹©µç¿É´ï 30 W
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ToughNet TN-4500A ϵÁÐ M12 Íø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»Á÷»úרΪ¹ìµÀ³µÁ¾ºÍ¹ìÅÔ×°Öõȹ콻ӦÓöøÉè¼Æ¡£ ´ËϵÁн»Á÷»úͨ¹ý M12 ÌÖÂÛºÍÆäËûÔ²ÐÎÌÖÂÛϸÃÜ¡¢Àο¿µÄÅþÁ¬£¬¿ÉÈ·±£ÔÚ¹¤ÒµÇéÐεÄÕñ¶¯ºÍ¹¥»÷ÏÂÎȹ̵ØÔËÐС£TN-4500A ϵÁÐÒÔÌ«Íø½»Á÷»úÅ䱸 12 ¸ö»ò 24 ¸ö°ÙÕ×ÒÔÌ«Íø M12 ¶Ë¿Ú£¬²¢ÌṩÇÐºÏ IEEE 802.3at/af ±ê×¼µÄ PoE ÐͺſÉÑ¡£»Ç§Õ×ÒÔÌ«ÍøÐͺÅÅ䱸 4 ¸öÖ§³Ö PoE ¹¦Ð§µÄǧÕ×ÒÔÌ«Íø½Ó¿Ú£¬²¢ÌṩÅÔ·Öм̹¦Ð§¿ÉÑ¡¡£±ðµÄ£¬¹âÏËÄ£×Ó»¹Ìṩ 2 ¸öǧÕ×¹âÏ˽ӿÚÄÚǶ 2 km ¶àÄ£¹âÏËÊÕ·¢Æ÷¡£PoE ÐͺŽ»Á÷»ú¿É×÷Ϊ¹©µç×°±¸ (PSE)¡£
ÿ¸ö¶Ë¿Ú¹©µç¿É´ï 30 W ¹¦ÂÊ£¬ÊʺÏΪÇÐºÏ IEEE 802.3at/af ±ê×¼µÄÊܵç×°±¸ (PD) ¹©µç£¬Èç IP ÉãÏñÍ·¡¢ÎÞÏß½ÓÈëµãºÍ IP µç»°¡£24 ÖÁ 110 VDC ¿í¹æÄ£µçÔ´ÊäÈëºÍ¸ôÀëË«µçÔ´ÊäÈ룬²»µ«¿ÉÔÚÈ«Çò²î±ðËùÔÚʹÓÃͬÑùµÄÊäÈëµçÔ´£¬»¹ÔöÇ¿ÁËͨѶϵͳµÄÎȹÌÐÔ¡£±ðµÄ£¬´ËϵÁн»Á÷»úÖ§³Ö -40 ÖÁ 75¡ãC ÊÂÇéζÈ£¬¿ÉÔÚ±°ÁÓÇéÐÎϾÙÐа²ÅÅ¡£TN-4500A ϵÁÐÒÔÌ«Íø½»Á÷»úÇÐºÏ EN 50155£¬°üÀ¨ÊÂÇéζȡ¢µçÔ´ÊäÈëµçѹ¡¢ÀËÓ¿¡¢ESD ºÍÕñ¶¯£¬ÒÔ¼°±£»¤Í¿²ãºÍµçÔ´¾øÔµ£¬Ê¹ÆäÊÊÓÃÓÚÖÖÖÖ¹¤ÒµÓ¦Óá£

ÆäËûÌصãºÍÓÅÊÆ
? ÔÚÿ̨½»Á÷»ú×ܹ¦ÂÊÔ¤ËãΪ 120W µÄÇéÐÎÏ£¬Ã¿¸ö PoE ¶Ë¿Ú¹©µç¿É´ï 30W µÄ¹¦ÂÊ
? IPv6 Ready ±ê¼ÇÈÏÖ¤£¨IPv6 ±ê¼ÇίԱ»áÈÏÖ¤£©
? ´ËÀཻÁ÷»úÇÐºÏ EN 50155 ±ê×¼²âÊÔ£¬ºÜÊÇÊʺϹìµÀ³µÁ¾Ó¦ÓÃ
? DHCP Option 82£¬ÓÃÓÚ²î±ðÕ½ÂÔ·ÖÅÉ IP µØµã
? Ö§³Ö Turbo Ring ºÍ Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms @ 250 ̨½»Á÷»ú£©£¬ÒÔ¼° RSTP/STP/MSTP ÍøÂçÈßÓà
? IGMP snooping ºÍ GMRP£¬ÓÃÓÚ¹ýÂË×é²¥Á÷Á¿
? Ö§³Ö EtherNet/IP ºÍ Modbus TCP ¹¤ÒµÒÔÌ«ÍøЭÒé
? »ùÓÚ¶Ë¿ÚµÄ VLAN¡¢IEEE 802.1Q VLAN ºÍ GVRP£¬¿É¼ò»¯ÍøÂçÍýÏë
? QoS£¨IEEE 802.1p/1Q ºÍ ToS/DiffServ£©Ö§³Ö¶ÔʵʱÁ÷Á¿µÄ·Ö¼¶ºÍÅÅÐò
? IEEE 802.3ad¡¢LACP£¬¿ÉÓÅ»¯ÍøÂç´ø¿í
? SNMPv1/v2c/v3 Ö§³Ö²î±ð¼¶±ðµÄÍøÂçÖÎÀí
? TACACS+¡¢SNMPv3¡¢IEEE 802.1X¡¢HTTPS ºÍ SSH£¬ÓÃÓÚÔöÇ¿ÍøÂçsafety
? RMON Ö§³Ö×Ô¶¯µÄÍøÂç¼à¿Ø
? ´ø¿íÖÎÀí£¬¿ÉÔ¤·À·ºÆð²»Îȹ̵ÄÍøÂç״̬
? »ùÓÚ MAC µØµãµÄ¶Ë¿ÚËø¶¨¹¦Ð§£¬±ÜÃâδ¾­ÊÚȨµÄ»á¼û
? Ö§³Ö¶Ë¿Ú¾µÏñ¹¦Ð§£¬±ãÓÚÔÚÏßµ÷ÊÔ
? ͨ¹ýµç×ÓÓʼþºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯·¢³öÒì³£ÖÒÑÔ
? ¿ìËÙ»»Ï߻ָ´
? LLDP Ö§³Öͨ¹ýÍøÂçÖÎÀíÈí¼þ×Ô¶¯·¢Ã÷ÍøÂçÍØÆË
? ͨ¹ý web ä¯ÀÀÆ÷¡¢Telnet/´®¿Ú console¡¢CLI ºÍ Windows ÖÎÀí¹¤¾ß¾ÙÐÐÉèÖÃ
? »·Â·±£»¤±ÜÃâÍøÂ绷·
? Ö§³ÖÃæ°åʽװÖÃ


ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ :2 x ¼ÌµçÆ÷Êä³ö£¬½ÓÄÉ 1 ¸ö M12 A-coded 5-pin ¹«Í·ÌÖÂÛ£¬´¿µç×èÐÔ¸ºÔØ£º1 A @ 30 VDC

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100/1000BaseT(X) ¶Ë¿Ú£¨M12 X-coded 8-pin ĸͷÌÖÂÛ£©: 
TN-4516A-4GTX-WV-T£º 4
TN-4516A-4GTX-WV-CT-T£º4
10/100BaseT(X) ¶Ë¿Ú£¨M12 D-coded 4-pin ĸͷÌÖÂÛ£©: 
TN-4516A ϵÁÐ·Ç PoE Ðͺţº12
TN-4524A/4528A ϵÁУº8
PoE ¶Ë¿Ú£¨10/100BaseT(X)£¬M12 D-coded 4-pin ĸͷÌÖÂÛ£©: 
TN-4516A ϵÁÐ PoE Ðͺţº12
TN-4524A/4528A ϵÁУº16
PoE ¶Ë¿Ú£¨10/100/1000BaseT(X)£¬M12 A-coded 8-pin ĸͷÌÖÂÛ£©: 
TN-4500A ϵÁÐ PoE Ðͺţº4
TN-4500A ϵÁÐ PoE ÐͺÅ£¬´ø¹âÏË»òÅÔ·£º2
10/100/1000BaseT(X) ¶Ë¿Ú£¨M12 X-coded 8-pin ĸͷÌÖÂÛ£¬´øÅÔ·¹¦Ð§£©: 
TN-4516 A-4GTXBP ϵÁУº4
TN-4516A-12PoE-2GPoE-2GTXBP ϵÁУº2
TN-4528A-16PoE-2GPoE-2GTXBP ϵÁУº2
10/100/1000BaseT(X) ¶Ë¿Ú£¬Q-ODC ¹âÏËÌÖÂÛ 
TN-4516A-12PoE-2GPoE-2GODC ϵÁУº2
TN-4528A-16PoE-2GPoE-2GODC ϵÁУº2
±ê×¼ :
IEEE 802.1D-2004£¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1p£¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.1Q£¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1s£¬ÓÃÓÚ¶àÌìÉúÊ÷ЭÒé (MSTP)
IEEE 802.1w£¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)
IEEE 802.1X£¬ÓÃÓÚÊÚȨÈÏÖ¤
IEEE 802.3£¬ÓÃÓÚ 10BaseT
IEEE 802.3ab£¬ÓÃÓÚ 1000BaseT(X)
IEEE 802.3ad£¬ÓÃÓÚ LACP ¶Ë¿Ú¾ÛºÏ
IEEE 802.3af/at£¬ÓÃÓÚ PoE/PoE+ Êä³ö£ºTN-4500A ϵÁÐ PoE ÐͺÅ
IEEE 802.3u£¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.3x£¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.3z£¬ÓÃÓÚ 1000BaseSX/LX/LHX/ZX

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ã²¥×ª·¢ :IP ¶¨Ïò¹ã²¥£¬¹ã²¥×ª·¢
ÉèÖÃÑ¡Ïî :ÏÂÁîÐнçÃæ (CLI)£¬Í¨¹ý´®¿Ú/Telnet/SSH µÄÏÂÁîÐнçÃæ (CLI)£¬Web Console (HTTP/HTTPS)£¬Windows ÖÎÀí¹¤¾ß
¹ýÂË :802.1Q¡¢GMRP¡¢GVRP¡¢IGMP v1/v2/v3¡¢»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢¾²Ì¬×é²¥
¹¤ÒµÐ­Òé :EtherNet/IP Adapter (Slave), Modbus TCP Server (Slave)
ÖÎÀí :
Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢DHCP Option 66/67/82¡¢DHCP Server/Client¡¢Flow control£¨Á÷Á¿¿ØÖÆ£©¡¢HTTP¡¢IPv4/IPv6¡¢LLDP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢QoS/CoS/ToS¡¢RARP¡¢RMON¡¢SMTP¡¢SNMP Inform¡¢SNMP Trap¡¢Syslog¡¢Telnet ºÍ Account Management£¨ÕË»§ÖÎÀí£©
MIB :Bridge MIB¡¢Ethernet-like MIB¡¢MIB-II¡¢P-BRIDGE MIB¡¢Q-BRIDGE MIB¡¢RMON MIB Groups 1¡¢2¡¢3¡¢9¡¢RSTP MIB
ÈßÓàЭÒé:Á´Â·¾ÛºÏ¡¢MSTP¡¢RSTP¡¢STP¡¢Turbo Chain¡¢Turbo Ring v1/v2¡¢´ø DRC µÄ Turbo Ring
SAFETY :¹ã²¥·ç±©±£»¤¡¢HTTPS/SSL¡¢ÍâµØÕÊ»§»á¼ûÖÎÀí¡¢TACACS+¡¢¶Ë¿ÚËø¶¨¡¢RADIUS¡¢ËÙÂÊÏÞÖÆºÍ SSH
¶ÔʱЧÀÍ:IEEE 1588 PTP v1/v2¡¢NTP Server/Client¡¢SNTP

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×é :256
VLAN ÊýÄ¿£¨max£©:64
VLAN ID ¹æÄ£ :VID 1 ÖÁ 4094

LED ½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
LED ָʾµÆ :STATE¡¢PWR1¡¢PWR2¡¢FAULT¡¢10/100/1000M

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú:M12 A-coded ¹«Í·ÌÖÂÛ

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊäÈëµçÁ÷ :
TN-4516A ϵÁÐ·Ç PoE Ðͺţºmax. 0.7 A @ 24 VDC
TN-4516A ϵÁÐ PoE Ðͺţºmax.7.0 A @ 24 VDC
TN-4524A ϵÁУºmax.6.5 A @ 24 VDC
TN-4528A ϵÁУºmax.7.2 A @ 24 VDC
ÊäÈëµçѹ :24/36/48/72/96/110 VDC
µçÔ´ÊäÈëÊýÄ¿:2
ÊÂÇéµçѹ :16.8 ÖÁ 137.5 VDC
¹ýÔصçÁ÷±£»¤ :Ö§³Ö
µçÔ´ÌÖÂÛ :M23 ÌÖÂÛ
·´½Ó±£»¤ :Ö§³Ö
PoE ¹¦ÂÊÔ¤Ëã×ÜÁ¿:TN-4500A ϵÁÐ PoE Ðͺţº120 W

 »úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç :½ðÊô
IP Æ·¼¶:IP42
³ß´ç :
TN-4516A ϵÁУº229.8 x 132 x 122.3 mm£¨9.05 x 5.20 x 4.81 Ó¢´ç£©
TN-4524A/4528A ϵÁУº347.8 x 132 x 122.3 mm£¨13.70 x 5.20 x 4.81 Ó¢´ç£©
ÖØÁ¿ :
TN-4516A ϵÁÐ·Ç PoE Ðͺţº1,965 g (4.32 lb)
TN-4516A ϵÁÐ PoE Ðͺţº2,607 g (5.74 lb)
TN-4516A ϵÁйâÏËÐͺţº2,705 g (5.96 lb)
TN-4524A ϵÁУº3,063 g (6.74 lb)
TN-4528A ϵÁУº3,304 g (7.27 lb)
TN-4528A ϵÁйâÏËÐͺţº3,375 g (7.44 lb)
×°Öà :µ¼¹ìʽװÖ㨿ÉÑ¡£©¡¢±Ú¹ÒʽװÖÃ
±£»¤ :TN-4500A ϵÁÐ -CT ÐͺţºPCB ±£»¤Í¿²ã

 ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéÎÂ¶È :-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£©:-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È :5 ÖÁ 95%£¨·ÇÀäÄý£©
º£°Î :2000 m

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EMC :EN 55032/24
EMS :
IEC 61000-4-2 ESD£º½Ó´¥£º6 kV£»¿ÕÆø£º8 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º20 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º2 kV£»Ðźţº2 kV
IEC 61000-4-5 Surge£ºµçÔ´£º2 kV£»Ðźţº2 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
×ÔÓÉÂäÌå :IEC 60068-2-31
ÉäƵ :FCC
¹ìµÀ½»Í¨:EN 50121-4¡¢EN 50155¡¢IEC 60571
¹ìµÀ»ðÔÖ·À»¤:EN 45545-2
SAFETY :IEC 60950-1¡¢UL 61010-2-201
¹¥»÷ :IEC 60068-2-27£¬IEC 61373£¬EN 50155
Õñ¶¯ :IEC 60068-2-64£¬IEC 61373£¬EN 50155

ÉùÃ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÂÌÉ«²úÆ· :RoHS¡¢CRoHS¡¢WEEE

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±ê×¼ :Telcordia SR332
ʱ¼ä :
TN-4516A-4GTX ϵÁУº599,164 Сʱ
TN-4516A-4GTXBP ϵÁУº589,421 Сʱ
TN-4516A-12PoE-4GPoE ϵÁУº428,680 Сʱ
TN-4516A-12PoE-2GPoE-2GTXBP ϵÁУº427,322 Сʱ
TN-4516A-12PoE-2GPoE-2GODC ϵÁУº421,432 Сʱ
TN-4524A-16PoE ϵÁУº429,402 Сʱ
TN-4528A-16PoE-4GPoE ϵÁУº393,894 Сʱ
TN-4528A-16PoE-2GPoE-2GTXBP ϵÁУº392,746 Сʱ
TN-4528A-16PoE-2GPoE-2GODC ϵÁУº387,767 Сʱ

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÆÚ:5Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿