ºèÔ˹ú¼Ê

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

EDR-G9010 ϵÁÐ

8 GbE Í­À + 2 GbE SFP ¶à¶Ë¿Ú¹¤ÒµÇ徲·ÓÉÆ÷

  •  ¼¯·À»ðǽ/NAT/VPN/·ÓÉÆ÷/½»Á÷»úÓÚÒ»Ìå
  •  Ê¹Óà VPN ½¨ÉèÔ¶³Ìsecurity»á¼ûËíµÀ
  •  Í¨¹ý״̬·À»ðǽ±£»¤Òªº¦×ʲú
  •  ½ÓÄÉ PacketGuard ÊÖÒÕ¼ì²â¹¤ÒµÐ­Òé
  •  ÍøÂçµØµãת»» (NAT) ÇáËɾÙÐÐÍøÂçÉèÖÃ
  •  Ö§³Ö RSTP/Turbo Ring ÈßÓàЭÒ飬ÔöÇ¿ÍøÂçÈßÓà
  •  »ùÓÚ IEC 62443/NERC CIP µÄsecurity¹¦Ð§
  •  Ö§³ÖsecurityÆô¶¯ÒÔ¼ì²éϵͳÍêÕûÐÔ
  •  Í¨¹ýÖÇÄÜ SettingCheck ¹¦Ð§¼ì²é·À»ðǽÉèÖÃ
  •  Ö§³Ö -40 ÖÁ 75¡ãC ÊÂÇéζȣ¨-T Ðͺţ©
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EDR-G9010 ϵÁÐÊÇÒ»Ì׸߶ȼ¯³ÉµÄ¹¤Òµ¼¶¶à¶Ë¿Úsecurity·ÓÉÆ÷£¬¼¯·À»ðǽ/NAT/VPN ºÍ¶þ²ãÍø¹ÜÐͽ»Á÷»ú¹¦Ð§ÓÚÒ»Ìå¡£ÕâÀà×°±¸×¨ÓÃÓÚÒªº¦Ô¶³Ì¿ØÖÆ»ò¼à¿ØÍøÂçÖлùÓÚÒÔÌ«ÍøµÄsecurityÓ¦Óá£ÕâÀàsecurity·ÓÉÆ÷ÌṩÁ˵ç×Ósecurity½çÏßÀ´±£»¤Òªº¦ÍøÂç×ʲú£¬ÆäÖаüÀ¨µçÁ¦Ó¦ÓÃÖеıäµçÕ¾¡¢±ÃÕ¾ÖеÄË®´¦Öóͷ£ÏµÍ³¡¢ÓÍÆøÓ¦ÓÃÖеÄÂþÑÜʽ¿ØÖÆϵͳ£¬ÒÔ¼°¹¤³§×Ô¶¯»¯ÖÐµÄ PLC/SCADA ϵͳ¡£


ʹÓÃseniorÍøÂçsecurity¹¦Ð§µÖÓù¶ñÒâÍþв
EDR-G9010 ϵÁÐǶÈëʽ·À»ðǽʹÓÃÕ½ÂÔ¹æÔò¿ØÖƲî±ðÐÅÍÐÇøÖ®¼äµÄÍøÂçÁ÷Á¿£¬¶øÍøÂçµØµãת»» (NAT) Ôò±£»¤ÄÚ²¿ÍøÂ磬ʹÆäÃâÊÜÀ´×ÔÍⲿÖ÷»úµÄδÊÚȨ»á¼û¡£ÐéÄâרÓÃÍøÂç (VPN) ¹¦Ð§ÔÚͨ¹ý¹«¹²»¥ÁªÍø»á¼ûרÓÃÍøÂçʱ£¬ÎªÓû§ÌṩsecurityͨѶËíµÀ¡£ Ϊ×ÊÖú±£»¤ÄúµÄ OT ×ʲúÃâÊÜÍøÂç¹¥»÷£¬EDR-G9010 ϵÁÐÖ§³ÖÉî²ãÊý¾Ý°ü¼ì²â (DPI)£¬ÒÔÕë¶ÔÖÖÖÖ OT Ìض¨Ð­Òé¼ì²éÍøÂçÊý¾Ý°üµÄÊý¾Ý²¿·Ö¡£


ʹÓÃÓû§ÓѺýçÃæºÍ¿ìËÙÉèÖüò»¯ÉèÖÃ
EDR-G9010 ϵÁеġ°½Ó¿ÚÀàÐÍ¿ìËÙÉèÖá±ÎªÓû§ÌṩÁËÒ»ÖÖ¼òÆÓµÄÒªÁ죬ֻÐèËIJ½¼´¿ÉÉèÖà WAN¡¢LAN ºÍÇŽӶ˿ÚÒÔʵÏÖ·Óɹ¦Ð§¡£±ðµÄ£¬¡°¿ìËÙ×Ô¶¯»¯ÉèÖÃÎļþ¡±¹¦Ð§Îª¹¤³ÌʦÃÇÌṩÁËÒ»¸ödzÒ×·½·¨À´ÉèÖ÷À»ðǽµÄ¹¤ÒµÐ­Òé¹ýÂ˹¦Ð§£¬°üÀ¨ EtherNet/IP¡¢Modbus TCP¡¢EtherCAT¡¢FOUNDATION Fieldbus ºÍ PROFINET¡£


¹¤Òµ¼¶Éè¼Æ£¬È·±£ÍøÂçÅþÁ¬²»ÖÐÖ¹
½èÖú EDR-G9010 ϵÁеĽáʵӲ¼þ£¬ÕâÀàsecurity·ÓÉÆ÷³ÉΪ±°ÁÓ¹¤ÒµÇéÐεÄÀíÏë֮ѡ£¬Æä¾ßÓпíÎÂÐͺÅ£¬¿ÉÔÚΣÏÕÌõ¼þºÍ -40 ÖÁ 75¡ãC µÄ¼«¶ËζÈÏ¿ɿ¿ÔËÐС£±ðµÄ£¬EDR-G9010 ϵÁÐÖ§³ÖcomprehensiveµÄ¶þ²ãºÍÈý²ãÈßÓà»úÖÆ£¬¿ÉÈ·±£ÄúµÄÍøÂçthroughout¼á³ÖÅþÁ¬¡£

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ 
´¿µç×èÐÔ¸ºÔØ£º1 A @ 24 VDC
°´Å¥ 
¸´Î»°´Å¥
Êý×ÖÊäÈëͨµÀ 
+13 ÖÁ +30 V ÌåÏÖ״̬ 1
-30 ÖÁ +3 V ÌåÏÖ״̬ 0
maximumÊäÈëµçÁ÷£º8 mA

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100/1000BaseT(X) ¶Ë¿Ú£¨RJ45 ÌÖÂÛ£© 
8
1000BaseSFP ²å²Û 
2
±ê×¼ 
IEEE 802.1Q£¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.3£¬ÓÃÓÚ 10BaseT
IEEE 802.3ab£¬ÓÃÓÚ 1000BaseT(X)
¾²Ì¬¶Ë¿Ú¾ÛºÏ
IEEE 802.3u£¬ÓÃÓÚ 100BaseT(X)
IEEE 802.3x£¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.3z£¬ÓÃÓÚ 1000BaseSX/LX/LHX/ZX

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ã²¥×ª·¢ 
IP ¶¨Ïò¹ã²¥£¬¹ã²¥×ª·¢
ÖÎÀí 
Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢DDNS¡¢DHCP Server/Client¡¢Web Console (HTTP/HTTPS)¡¢LLDP¡¢QoS/CoS/ToS¡¢SNMPv1/v2c/v3¡¢Telnet¡¢TFTP¡¢HTTPS¡¢SSH
ÈßÓàЭÒé 
RSTP, STP, Turbo Ring v2
·ÓÉ 
ÍÌÍÂÁ¿£ºÃ¿Ãë 350K ¸öÊý¾Ý°ü£¨maximum 1500 Mbps£©
·Óɱí 
Most Duo 4K ¸ö·Óɱí
²¢·¢ÅþÁ¬ 
Most Duo 400K ¸ö
ÿÃëµÄÅþÁ¬Êý 
Most Duo 20K ¸ö
·ÓÉÈßÓà 
VRRP
safety 
safetyÆô¶¯¡¢IPsec¡¢L2TP (server)¡¢RADIUS¡¢ÐÅÍлá¼û¿ØÖÆ
¶ÔʱЧÀÍ 
NTP Server/Client£¬SNTP
µ¥²¥Â·ÓÉ 
OSPF£¬RIPV1/V2£¬¾²Ì¬Â·ÓÉ
×鲥·ÓÉ 
¾²Ì¬Â·ÓÉ
¹ýÂË 
IGMP v1/v2/v3

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
VLAN ID ¹æÄ£ 
VID 1 ÖÁ 4094
IGMP ·Ö×é 
256
maximum VLAN ÊýÄ¿ 
16

LED ½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
LED ָʾµÆ 
PWR1¡¢PWR2¡¢STATE¡¢MSTR/H.TC¡¢CPLR/T.TC¡¢VRRP/HA¡¢VPN¡¢USB

DoS ºÍ DDoS ±£»¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÖÒÕ 
ARP-Flood, FIN Scan, ICMP-Death, NEWWithout-SYN Scan, NMAP-ID Scan, NMAPXmas Scan, Null Scan, SYN/FIN Scan, SYN/RST Scan, SYN-Flood, Xmas Scan

safety·À»¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ýÂË 
DDoS¡¢ÒÔÌ«ÍøЭÒé¡¢ICMP¡¢IP µØµã¡¢MAC µØµã¡¢¶Ë¿Ú
¿ìËÙ×Ô¶¯»¯ÉèÖÃÎļþ 
DNP¡¢EtherCAT¡¢EtherNet/IP¡¢FOUNDATION Fieldbus¡¢FTP¡¢HTTP¡¢IEC 60870-104¡¢IPsec¡¢L2TP¡¢LonWorks¡¢Modbus TCP¡¢PPTP¡¢PROFINET¡¢RADIUS¡¢SSH¡¢Telnet
״̬¼ì²â 
·ÓÉÆ÷·À»ðǽ
͸Ã÷ (bridge) ·À»ðǽ
Éî²ãÊý¾Ý°ü¼ì²â 
δÀ´µÄ¹Ì¼þ¸üн«Ö§³ÖÆäËûЭÒé¡£
ÍÌÍÂÁ¿ 
ÿÃëMost Duo 350K ¸öÊý¾Ý°ü£¨maximum 1500 Mbps£©

IPsec VPN

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÈÏÖ¤ 
MD5 ºÍ SHA (SHA-256)
RSA£¨ÃÜÔ¿´óС£º1024 룬2048 룩
X.509 v3 Ö¤Êé
VPN ²¢·¢ËíµÀ 
Most Duo 250 ¸ö IPsec VPN ËíµÀ
¼ÓÃÜ 
DES¡¢3DES¡¢AES-128¡¢AES-192¡¢AES-256
ЭÒé 
IPsec¡¢L2TP (server)¡¢PPTP (client)
ÍÌÍÂÁ¿ 
maximum 300 Mbps£¨Ìõ¼þ£ºAES-256¡¢SHA-256£©

NAT

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÌØÕ÷ 
1 ת 1£¬N ת 1£¬¶Ë¿Úת·¢

ʵʱ·À»ðǽ/VPN ÊÂÎñÈÕÖ¾

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÎñÀàÐÍ 
·À»ðǽÊÂÎñ¡¢VPN ÊÂÎñ
½Ó¿Ú 
ÍâµØ´æ´¢¡¢SNMP Trap¡¢Syslog server

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú 
RS-232£¨TxD¡¢RxD¡¢GND£©£¬3-pin£¨115200¡¢n¡¢8¡¢1£©
ÌÖÂÛ 
USB Type-C

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÅþÁ¬ 
¿É²ðж½ÓÏ߶Ë×Ó
ÊäÈëµçѹ 
12/24/48 VDC
ÊäÈëµçÁ÷ 
1.51 A @ 12 VDC
0.70 A @ 24 VDC
0.35 A @ 48 VDC
·´½Ó±£»¤ 
Ö§³Ö

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç 
½ðÊô
³ß´ç 
58 x 135 x 105 mm£¨2.28 x 5.31 x 4.13 Ó¢´ç£©
ÖØÁ¿ 
1030 g (2.27 lb)
×°Öà
µ¼¹ìʽװÖ㬱ڹÒʽװÖ㨴ø¿ÉÑ¡Ì×¼þ£©

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéζȠ
±ê×¼Ðͺţº-10 ÖÁ 60¡ãC£¨14 ÖÁ 140¡ãF£©
¿íÎÂÐͺţº-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£© 
-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È 
5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
safety 
UL 62368-1
EMC 
EN 55032/35
EMI 
CISPR 32£¬FCC Part 15B Class A
EMS 
IEC 61000-4-2 ESD£º½Ó´¥£º8 kV£»¿ÕÆø£º15 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º20 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º4 kV£»Ðźţº4 kV
IEC 61000-4-5 Surge£ºµçÔ´£º2 kV£»Ðźţº4 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
¹ìµÀ½»Í¨ 
EN 50121-4
½»Í¨¿ØÖÆ 
NEMA TS2
º£Ê 
IEC 60945
±äµçÕ¾ 
IEEE 1613£¬IEC 61850-3 Edition 2.0
¹¥»÷ 
IEC 60068-2-27
×ÔÓÉÂäÌå 
IEC 60068-2-32
Õñ¶¯ 
IEC 60068-2-6

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä 
1,080,807 Сʱ
±ê×¼ 
Telcordia (Bellcore)£¬GB

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÏÞÆÚ 
5 Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿